KRAUS & NAIMER KG126 - Electrical Data 1.12.2006

Switch features:
- S2 (88x88mm) Front element size (can be changed by mountings and optional extras)
- Designed for vertical wiring (resp. horizontal for -V mountings: e.g. VE-V, FS1-V)
- Forced opening and closing of the contacts; All terminals in one plane
- Approved by UL as 'disconnect switch for use in motor circuits'

Approvals:

Approved Confirms to requirements No listing required
CCC, CSA, CUR, CURUS, GOST, UR BS EN, CH, D, FI, IEC, N, ÖVE, S, VDE

BS EN...BS EN 60947 - British Standards Institution, CCC...CCC - China Compulsory Certification, CH...Schweizerischer Elektrotechnischer Verein, CSA...Canadian Standards Association, CUL...Canadian National Standards - Listed, CULUS...Canadian National and United States Standards - Listed, CUR...Canadian National Standards - Recognized, CURUS...Canadian National and United States Standards - Recognized, D...Danmarks Elektriske Materiellkontrol, FI...Sähkötarkastuskeskus, GOST...GOST - gosudarstvennyj standard, IEC...IEC 60947 - International Electrical Commission (IEC) Recommendation, N...Norges Elektriske Materiellkontroll, ÖVE...Österreichischer Verband für Elektrotechnik, RuMRS...Russian Maritime Register of Shipping, S...Svenska Elektriska Materielkontrollanstalten, UL...United States Standards - Listed, UR...United States Standards - Recognized, VDE...VDE 0660 - Verband Deutscher Elektrotechniker

Note the remarks in the approval table!: here or at http://www.krausnaimer.com/0/apps.htm

AC-Values:

IEC 60947-3, EN 60947-3, VDE 0660 part 107:
Rated Operational Voltage Ue1000V (Suitable for no load switching applications (AC-20A) above 690V)1)
Rated Insulation Voltage Ui1000V (Suitable for no load switching applications (AC-20A) above 690V)1)
Rated Thermal Current Iu/Ith125A 2)
Rated Operational Current Ie
AC-20A No-load operation125A 2)
AC-21A Switching of resistive loads, including moderate overloads
For switching of power >1kW 125A 2)
AC-22A Switching of combined resistive or low inductive loads including moderate overloads
220V-500V:   
125A 2)
660V-690V:   
100A 2)
Rated Utilization Category
AC-3 Direct-on-line starting, star-delta starting
3 phase, 3 pole
220V-240V:   
22kW 2)
380V-440V:   
37kW 2)
500V-500V:   
45kW 2)
660V-690V:   
30kW 2)
AC-23A Frequent switching of motors or other high inductive loads
3 phase, 3 pole
220V-240V:   
30kW 2)
380V-440V:   
45kW 2)
500V-500V:   
55kW 2)
660V-690V:   
37kW 2)
Auxiliary contacts
Rated Insulation Voltage Ui690V 1)
Rated Impulse Withstand Voltage Uimp6kV 1)
Rated Thermal Current Iu/Ith16A 2)
AC-21A Switching of resistive loads, including moderate overloads16A 2)
AC-15 Switching of control devices, contactors, valves etc.
110V-240V:   
6A 2)
380V-440V:   
3A 2)
500V-500V:   
1.5A 2)
Short Circuit Protection: Max. fuse size (gl-characteristic)16A 2)
1)...IEC 60947-3, EN 60947-3, VDE 0660 part 107 - Valid for lines with grounded common neutral termination, overvoltage category III, Other values on request.
2)...IEC 60947-3, EN 60947-3, VDE 0660 part 107

UL/Canada:
Rated Voltage600V 1)
Rated Insulation Voltage Ui600V 1)
Rated Thermal Current150/125A ON-OFF / Double throw switch (Valid when connected with wire rated for 75°C)1)
Ampere Rating - Resistive or low inductive loads
For switching of power >1kW 150/125A ON-OFF / Double throw switch (Valid when connected with wire rated for 75°C)1)
Ratings
Standard motor load, DOL Rating (similar AC-3)
3 phase, 3 pole
110V-120V:   
15HP 2)
220V-240V:   
30HP 2)
440V-480V:   
60HP 2)
550V-600V:   
60HP 2)
Auxiliary contacts
Rated Voltage600V 2)
Rated Thermal Current10A 2)
Ampere Rating - Resistive or low inductive loads10A 2)
Pilot Duty, HeavyA600VAC 2)
1)...UL/Canada - Refer to International Standards and Approvals
2)...UL/Canada

General:

Minimum Voltage on request
Rated Impulse Withstand Voltage Uimp8kV 1)
Short Circuit Protection
Max. fuse size (gL/gG-characteristic)125A
Rated short-time withstand current (1s-current)2500A
Ambient Temperature of Stages (for switches with electro-mechanical accessories refer to optional extra)
open at 100% Iu/Ith 50°C during 24 hours with peaks up to 55°C
enclosed at 100% Ithe 35°C during 24 hours with peaks up to 40°C
Storage temperature -40°C to 85°C (in case of temperature below -5°C no shock load permissible)
Terminal lead material copper wires only
Max. Permissible Wire Gage
for box terminal Single-core or stranded wire95mm2
AWG 3/0
for box terminal Flexible wire without sleeving70mm2
AWG 2/0
for box terminal Flexible wire with sleeving70mm2
For connections with cable terminal or copper busbar
Connecting screwM10
Length of connecting screw20mm
Max. width20mm
Max. width with protective cover25mm
Auxiliary contacts
Max. Permissible Wire Gage: Single-core or stranded wire2.5mm2
AWG 12
Max. Permissible Wire Gage: Flexible wire2.5mm2
AWG 14
Max. Permissible Wire Gage: Flexible wire with sleeving in accordance with DIN 462282.5mm2
1)...IEC 60947-3, EN 60947-3, VDE 0660 part 107 - Valid for lines with grounded common neutral termination, overvoltage category III, Other values on request.

Additional information:
The power line connection has to be wired over separate UL approved terminals.