KRAUS & NAIMER C200-4 - Electrical Data 25.8.2009

Switch features:
- S2 (88x88mm) Front element size (can be changed by mountings and optional extras)
- Terminal screws accessible laterally (resp. from above and below for -V mountings)
- Designed for horizontal wiring (resp. vertical for -V mountings: e.g. VE-V, FS1-V)

Approvals:

Approved Confirms to requirements No listing required
BS EN, CH, IEC, VDE D, FI, N, ÖVE, S

BS EN...BS EN 60947 - British Standards Institution, CCC...CCC - China Compulsory Certification, CH...Schweizerischer Elektrotechnischer Verein, CSA...Canadian Standards Association, CUL...Canadian National Standards - Listed, CULUS...Canadian National and United States Standards - Listed, CUR...Canadian National Standards - Recognized, CURUS...Canadian National and United States Standards - Recognized, D...Danmarks Elektriske Materiellkontrol, FI...Sähkötarkastuskeskus, GOST...GOST - gosudarstvennyj standard, IEC...IEC 60947 - International Electrical Commission (IEC) Recommendation, N...Norges Elektriske Materiellkontroll, ÖVE...Österreichischer Verband für Elektrotechnik, RuMRS...Russian Maritime Register of Shipping, S...Svenska Elektriska Materielkontrollanstalten, UL...United States Standards - Listed, UR...United States Standards - Recognized, VDE...VDE 0660 - Verband Deutscher Elektrotechniker

Note the remarks in the approval table!: here or at http://www.krausnaimer.com/0/apps.htm

AC-Values:

IEC 60947-3, EN 60947-3, VDE 0660 part 107:
Rated Operational Voltage Ue690V 1)
Rated Insulation Voltage Ui690V 1)
Rated Thermal Current Iu/Ith200A 2)
Breaking Capacity
220V-240V:   
1100A 2)
380V-440V:   
1100A 2)
660V-690V:   
490A 2)
Rated Operational Current Ie
AC-20A No-load operation200A 2)
AC-21A Switching of resistive loads, including moderate overloads
For switching of power >1kW 200A 2)
AC-22A Switching of combined resistive or low inductive loads including moderate overloads
220V-500V:   
150A 2)
660V-690V:   
125A 2)
Rated Utilization Category
AC-2 Slip ring motor starting, reversing and plugging, star-delta starting 3 phase, 3 pole
220V-240V:   
37kW 2)
380V-440V:   
55kW 2)
500V-500V:   
75kW 2)
660V-690V:   
55kW 2)
AC-3 Direct-on-line starting, star-delta starting
3 phase, 3 pole
220V-240V:   
22kW 2)
380V-440V:   
37kW 2)
500V-500V:   
37kW 2)
660V-690V:   
30kW 2)
1 phase, 2 pole
110V-120V:   
5.5kW 2)
220V-240V:   
11kW 2)
380V-440V:   
18.5kW 2)
AC-4 Direct-on-line starting, reversing, plugging and inching
3 phase, 3 pole
220V-240V:   
10kW 2)
380V-440V:   
15kW 2)
500V-500V:   
15kW 2)
660V-690V:   
15kW 2)
1 phase, 2 pole
110V-120V:   
2.2kW 2)
220V-240V:   
4kW 2)
380V-440V:   
7.5kW 2)
AC-23A Frequent switching of motors or other high inductive loads
3 phase, 3 pole
220V-240V:   
37kW 2)
380V-440V:   
75kW 2)
500V-500V:   
90kW 2)
660V-690V:   
55kW 2)
1 phase, 2 pole
110V-120V:   
11kW 2)
220V-240V:   
22kW 2)
380V-440V:   
37kW 2)
1)...IEC 60947-3, EN 60947-3, VDE 0660 part 107 - Valid for lines with grounded common neutral termination, overvoltage category III, Other values on request.
2)...IEC 60947-3, EN 60947-3, VDE 0660 part 107


DC-Values:

Resistive loads (T<=1ms)
DC switching capacity applies to ON/OFF switches. Switching capacity for other configurations on request.
Number of series contact(s) DC-switching capacity
1 2 3 4 5 6 8
48V 95V 140V 190V 240V 290V 350V 150A

Inductive load (T=50ms)
DC switching capacity applies to ON/OFF switches. Switching capacity for other configurations on request.
Number of series contact(s) DC-switching capacity
1 2 3 4 5 6 8
24V 48V 70V 95V 120V 145V 190V 150A
30V 60V 90V 120V 150V 180V 240V 50A

General:

Minimum Voltage on request
Power loss per contact at Iu6.8W
Resistance to vibration on request
Resistance to shock min. 5g, 30ms
Rated Impulse Withstand Voltage Uimp6kV 1)
Short Circuit Protection
Max. fuse size (gL/gG-characteristic)200A
Rated short-time withstand current (1s-current)2000A
Ambient Temperature of Stages (for switches with electro-mechanical accessories refer to optional extra)
open at 100% Iu/Ith 55°C during 24 hours with peaks up to 60°C
enclosed at 100% Ithe 35°C during 24 hours with peaks up to 40°C
Storage temperature -40°C to 85°C (in case of temperature below -5°C no shock load permissible)
Terminal lead material copper wires only
Max. Permissible Wire Gage
Single-core or stranded wire95mm2 Cable lug must accept M8 screw.
Flexible wire95mm2 Cable lug must accept M8 screw.
1)...IEC 60947-3, EN 60947-3, VDE 0660 part 107 - Valid for lines with grounded common neutral termination, overvoltage category III, Other values on request.