MOTOR STARTER Type M10D51

Code No
(Points [.] are placeholders for individual digits. See footnote for details.)
IMOT
 
*)
View dimensional drawing
1.3A
View dimensional drawing
1.9A
View dimensional drawing
2.8A
View dimensional drawing
4.2A
View dimensional drawing
6.2A
View dimensional drawing
9.2A
View dimensional drawing
12.75A
View dimensional drawing
.... depends on the coil frequency and voltage. Click here to view coil types

*): without thermal overload relay

Rated Values 1 phase / 2 pole:

Operational Voltage
220-240 V
380-440 V
500 V
660-690 V
Max. Motor Capacity [kW]
1.1
2.2
2.2
2.2
Max. Motor Capacity [HP]
1.5
3
3
3

Contactor:
S1010 ..../2010. For further information about the contactor click here.
 
Thermal Overload Relay:
T9E2: T9E2 is a special design variant of T9E1 modified for the use as a part of 2 pole motor starters. For information about the max. fuse size click here.
 
Enclosure:
KL with IP65
 
Conduit Entries:
Multi access entries 19 mm Ø for PG11 and 23 mm Ø for PG16
 
Features:
Wired unit with selector switch (CG4 A210) and reset unit.

Main Circuit
Control Circuit
 
*): Neutral conductor or K1-5
**): External control contact; e.g. connected to a float switch
Show Guide & Help